{"id":3885,"date":"2026-11-11T00:00:56","date_gmt":"2026-11-10T16:00:56","guid":{"rendered":"https:\/\/www.soonestpower.com\/?p=3885"},"modified":"2026-11-13T10:21:40","modified_gmt":"2026-11-13T02:21:40","slug":"solar-pump-controller-faults-read-the-symptoms-before-you-replace-anything","status":"publish","type":"post","link":"https:\/\/www.soonestpower.com\/fr\/solar-pump-controller-faults-read-the-symptoms-before-you-replace-anything\/","title":{"rendered":"Pannes du contr\u00f4leur de pompe solaire\u00a0: Lisez les sympt\u00f4mes avant de remplacer quoi que ce soit"},"content":{"rendered":"<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3886\" src=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/Solar-Pump-Controller-Faults-Read-the-Symptoms-Before-You-Replace-Anything.webp\" alt=\"Pannes du contr\u00f4leur de pompe solaire\u00a0: Lisez les sympt\u00f4mes avant de remplacer quoi que ce soit\" width=\"750\" height=\"937\" srcset=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/Solar-Pump-Controller-Faults-Read-the-Symptoms-Before-You-Replace-Anything.webp 750w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/Solar-Pump-Controller-Faults-Read-the-Symptoms-Before-You-Replace-Anything-240x300.webp 240w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/Solar-Pump-Controller-Faults-Read-the-Symptoms-Before-You-Replace-Anything-10x12.webp 10w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/Solar-Pump-Controller-Faults-Read-the-Symptoms-Before-You-Replace-Anything-600x750.webp 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/p>\n<p>Un programmateur qui se d\u00e9clenche est g\u00e9n\u00e9ralement un simple indicateur, pas la cause du probl\u00e8me. Le niveau d'eau a baiss\u00e9. La turbine est us\u00e9e. Un matin froid a fait d\u00e9passer la tension d'entr\u00e9e maximale aux arroseurs. Ou bien le bo\u00eetier est install\u00e9 de mani\u00e8re \u00e0 \u00eatre expos\u00e9 au soleil toute la journ\u00e9e. Du c\u00f4t\u00e9 du distributeur, le programmateur est d'abord mis en cause, puis d\u00e9pann\u00e9 en dernier, et chaque remplacement envoy\u00e9 pr\u00e9matur\u00e9ment co\u00fbte \u00e0 l'agriculteur deux semaines sans eau, sans compter les frais de port.<\/p>\n<p>Quel que soit l'affichage, il indique qu'une protection a fonctionn\u00e9 correctement. Il ne s'agit pas d'un diagnostic concernant l'\u00e9lectronique. La plupart des d\u00e9clenchements sont li\u00e9s au niveau d'eau, \u00e0 la tuyauterie, \u00e0 la tension des panneaux solaires ou \u00e0 la chaleur. Les distributeurs qui re\u00e7oivent ces appels placent g\u00e9n\u00e9ralement le bo\u00eetier en bas de la liste des causes possibles.<\/p>\n<p>Les pi\u00e8ces \u00e0 v\u00e9rifier ci-dessous suivent une r\u00e8gle simple\u00a0: diagnostiquer avant d\u2019acheter. Elles sont class\u00e9es par ordre d\u00e9croissant de prix, afin de ne jamais commencer par la plus ch\u00e8re.<\/p>\n<h2><strong>V\u00e9rifiez l'eau avant les appareils \u00e9lectroniques<\/strong><\/h2>\n<p>Un d\u00e9faut de fonctionnement \u00e0 sec n'est pas un d\u00e9faut du contr\u00f4leur. Cela signifie qu'aucune eau n'a circul\u00e9 dans la pompe.<\/p>\n<p>Le niveau d'eau statique baisse pendant la saison s\u00e8che. Une pompe r\u00e9gl\u00e9e \u00e0 40 m\u00e8tres il y a deux ans peut se trouver au-dessus de la nappe phr\u00e9atique d\u00e8s midi.<\/p>\n<p>Cela a fonctionn\u00e9 toute la matin\u00e9e, lorsque le niveau \u00e9tait plus \u00e9lev\u00e9. Personne ne s'en est aper\u00e7u, car l'eau est arriv\u00e9e.<\/p>\n<p>Posez un tuyau et mesurez le niveau, puis comparez-le \u00e0 la mesure relev\u00e9e le jour de l'installation. Cette valeur explique plus de pannes que n'importe quel code d'erreur.<\/p>\n<p>Apr\u00e8s \u00e7a, les probl\u00e8mes les plus b\u00eates. Quelqu'un d\u00e9couvre une cr\u00e9pine d'aspiration bouch\u00e9e, un tuyau d'aspiration affaiss\u00e9, ou encore le clapet de pied qui ne s'amorce plus depuis trois mois et que personne n'a v\u00e9rifi\u00e9.<\/p>\n<h2><strong>R\u00e9p\u00e9tition g\u00e9n\u00e9rale qui se r\u00e9sout d'elle-m\u00eame dans l'apr\u00e8s-midi<\/strong><\/h2>\n<p>Les bons r\u00e9gulateurs red\u00e9marrent automatiquement quelques minutes apr\u00e8s un essai \u00e0 vide.<\/p>\n<p>Si une personne doit r\u00e9initialiser l'appareil manuellement apr\u00e8s chaque trajet, le diagnostic est d\u00e9j\u00e0 erron\u00e9. La protection fonctionne, mais la configuration sous-jacente est d\u00e9faillante.<\/p>\n<p>L'exp\u00e9rience sur le terrain montre que l'une de ces deux modifications permet de r\u00e9soudre la quasi-totalit\u00e9 des probl\u00e8mes\u00a0: soit la pompe descend plus profond\u00e9ment dans le forage, soit le seuil de fonctionnement \u00e0 sec est relev\u00e9, ce qui d\u00e9clenche l'arr\u00eat plus t\u00f4t, lorsque le moteur dispose encore d'une temp\u00e9rature de refroidissement suffisante pour red\u00e9marrer.<\/p>\n<p>Ne d\u00e9sactivez pas la protection. Un moteur sans balais fonctionnant \u00e0 sec pendant vingt minutes perd ses joints d'\u00e9tanch\u00e9it\u00e9. L'eau se retrouve alors dans le bobinage au lieu du r\u00e9servoir.<\/p>\n<h2><strong>Surtension \u00e0 neuf heures du matin<\/strong><\/h2>\n<p>Cela ressemble \u00e0 un probl\u00e8me de contr\u00f4leur. C'est presque toujours un probl\u00e8me de r\u00e9seau.<\/p>\n<p>La tension des panneaux augmente lorsque les cellules sont froides. Prenons l'exemple d'une cha\u00eene affichant 380 V par une chaude apr\u00e8s-midi. Par une matin\u00e9e fra\u00eeche et ensoleill\u00e9e, cette m\u00eame cha\u00eene affiche 420 V, voire plus. Le contr\u00f4leur d\u00e9tecte cette tension et coupe l'alimentation, assurant ainsi sa protection, comme pr\u00e9vu.<\/p>\n<p>On compare cette valeur \u00e0 la tension \u00e0 vide, c'est-\u00e0-dire la tension produite par la cha\u00eene sans charge. Elle ne d\u00e9passe jamais cette valeur. On la compare ensuite \u00e0 la limite d'entr\u00e9e du contr\u00f4leur lors des conditions m\u00e9t\u00e9orologiques les plus froides que le site puisse conna\u00eetre. Jamais lors d'une matin\u00e9e ordinaire. Les d\u00e9clenchements sont masqu\u00e9s par les moyennes, et les moyennes masquent les d\u00e9clenchements.<\/p>\n<p>Une cha\u00eene de caract\u00e8res qui fonctionnait correctement en juin peut disjoncter tous les matins en d\u00e9cembre.<\/p>\n<p>Rien ne remplace le mat\u00e9riel dans ce cas. La solution r\u00e9side dans le c\u00e2blage\u00a0: soit moins de panneaux en s\u00e9rie, soit une r\u00e9partition s\u00e9rie-parall\u00e8le compl\u00e8tement diff\u00e9rente.<\/p>\n<p>On confond souvent marge de tension et hauteur manom\u00e9trique. Ce sont des grandeurs diff\u00e9rentes, mais le dimensionnement doit prendre en compte les deux, car elles d\u00e9terminent les performances du syst\u00e8me final.<\/p>\n<h2><strong>Surcharge et le sable qui n'\u00e9tait pas l\u00e0 l'ann\u00e9e derni\u00e8re<\/strong><\/h2>\n<p>Une surcharge signifie que le moteur a consomm\u00e9 plus de courant que la limite autoris\u00e9e. Cela peut parfois indiquer une d\u00e9faillance du moteur.<\/p>\n<p>Sur le terrain, c'est plus souvent la turbine qui est us\u00e9e que le moteur. Ou bien le forage a commenc\u00e9 \u00e0 contenir du sable, ce que personne ne remarque avant que la pompe ne remonte.<\/p>\n<p>Remontez la pompe \u00e0 la surface et passez votre pouce sur le bord d'attaque de la turbine. Si la surface est ray\u00e9e plut\u00f4t que lisse, cela signifie que le sable a rong\u00e9 la pompe pendant des mois.<\/p>\n<p>Une pompe qui alimente une eau sableuse pendant une saison finit par perdre sa charge sans bruit. Le probl\u00e8me survient plus tard, lorsque le niveau baisse et que la charge augmente en cons\u00e9quence.<\/p>\n<p>Le contr\u00f4leur continue de prot\u00e9ger le moteur. Cela ne revient pas \u00e0 r\u00e9parer le puits.<\/p>\n<h2><strong>Temp\u00e9ratures \u00e9lev\u00e9es \u00e0 deux heures de l'apr\u00e8s-midi<\/strong><\/h2>\n<p>Placez un contr\u00f4leur dans un bo\u00eetier m\u00e9tallique en plein soleil\u00a0: il se d\u00e9clenchera par une chaude apr\u00e8s-midi. Puis, l\u2019apr\u00e8s-midi suivante, il se d\u00e9clenchera \u00e0 nouveau. Demandez \u00e0 l\u2019agriculteur \u00e0 quelle heure il se d\u00e9clenche\u00a0; vous obtiendrez la m\u00eame r\u00e9ponse \u00e0 chaque fois, ce qui devrait indiquer que la chaleur est en cause.<\/p>\n<p>Les installateurs comp\u00e9tents placent le contr\u00f4leur \u00e0 un endroit ombrag\u00e9, permettant une bonne circulation de l'air autour du dissipateur thermique. Un tissu d'ombrage et un d\u00e9gagement de 30 centim\u00e8tres suffisent g\u00e9n\u00e9ralement \u00e0 r\u00e9soudre ces probl\u00e8mes, contrairement au remplacement du contr\u00f4leur.<\/p>\n<p>Un trajet le matin, c'est une autre histoire. Regardez le moteur \u00e0 ce moment-l\u00e0. Une pompe qui tourne \u00e0 une fr\u00e9quence inadapt\u00e9e chauffe avant m\u00eame que le soleil ne soit fort.<\/p>\n<h2><strong>Quand la manette est vraiment morte<\/strong><\/h2>\n<p>La mort r\u00e9elle se manifeste autrement. Une panne r\u00e9elle est visible\u00a0: de l\u2019eau s\u2019accumule \u00e0 l\u2019int\u00e9rieur du bo\u00eetier, une borne est noircie par la chaleur, ou un orage a frapp\u00e9 \u00e0 proximit\u00e9. La foudre, quant \u00e0 elle, se propage g\u00e9n\u00e9ralement du c\u00f4t\u00e9 courant continu et d\u00e9truit le contr\u00f4leur tandis que les panneaux restent intacts.<\/p>\n<p>Installez la pi\u00e8ce de rechange, puis placez un dispositif de protection contre les surtensions c\u00f4t\u00e9 courant continu et mettez \u00e0 la terre l'ensemble du syst\u00e8me comme il aurait d\u00fb l'\u00eatre d\u00e8s le d\u00e9part.<\/p>\n<p>Maintenez cette limite stricte, d\u00e9lib\u00e9r\u00e9ment. Si vous l'\u00e9largissez, vous risquez de remplacer un bo\u00eetier innocent au lieu du v\u00e9ritable probl\u00e8me. Testez un contr\u00f4leur suspect sur un r\u00e9seau fonctionnel et faites-le fonctionner pendant un apr\u00e8s-midi\u00a0; si le d\u00e9clenchement suit le bo\u00eetier, remplacez-le. Un d\u00e9faut qui reste localis\u00e9 sur le terrain n'\u00e9tait jamais d\u00fb au bo\u00eetier.<\/p>\n<p>La foudre frappe l'objet terrestre le plus haut qu'elle puisse trouver.<\/p>\n<h2><strong>Ce que la pompe devrait offrir<\/strong><\/h2>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3888\" src=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump.webp\" alt=\"Pompe \u00e0 eau solaire AC\/DC SOONEST\" width=\"750\" height=\"750\" srcset=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump.webp 750w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump-300x300.webp 300w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump-150x150.webp 150w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump-12x12.webp 12w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump-600x600.webp 600w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/11\/SOONEST-AC-DC-Solar-Powered-Water-Pump-100x100.webp 100w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/p>\n<p>Le <strong><a href=\"https:\/\/www.soonestpower.com\/fr\/product\/pompe-solaire\/\"><u>Pompe \u00e0 eau solaire AC\/DC SOONEST<\/u><\/a><\/strong>\u00a0Elle a \u00e9t\u00e9 sp\u00e9cifi\u00e9e pr\u00e9cis\u00e9ment en fonction de cette liste d'appels, int\u00e9grant comme protections standard la marche \u00e0 sec, la surcharge, la basse tension, la haute temp\u00e9rature, l'inversion de polarit\u00e9 et la r\u00e9gulation de vitesse.<\/p>\n<p>Le suivi MPPT assure un rendement de conversion d'environ 85 % et maintient le g\u00e9n\u00e9rateur photovolta\u00efque \u00e0 sa tension optimale. Il int\u00e8gre un moteur \u00e0 aimant permanent sans balais, choisi pour son absence de balais \u00e0 entretenir sur site.<\/p>\n<p>La structure est en alliage d'aluminium, les enroulements sont moul\u00e9s en r\u00e9sine et l'\u00e9tanch\u00e9it\u00e9 est excellente. Lors des saisons o\u00f9 les t\u00eates d'injection sont inond\u00e9es, cette \u00e9tanch\u00e9it\u00e9 fait toute la diff\u00e9rence entre une pompe et un presse-papier.<\/p>\n<p>Ce syst\u00e8me ne comporte volontairement aucune batterie entre le panneau solaire et la pompe. Durant les p\u00e9riodes de s\u00e9cheresse, la version AC\/DC fonctionne sur secteur ou avec un g\u00e9n\u00e9rateur pilot\u00e9 par le m\u00eame contr\u00f4leur.<\/p>\n<p>Lorsqu'une pompe partage un emplacement avec une maison ou une chambre froide, un seul groupe alimente g\u00e9n\u00e9ralement un <strong><a href=\"https:\/\/www.soonestpower.com\/fr\/product\/serie-aio\/\"><u>unit\u00e9 de stockage tout-en-un<\/u><\/a><\/strong>Les sites de ce type ont moins de bo\u00eetiers au mur et un seul manuel au lieu de trois.<\/p>\n<h2><strong>Une proc\u00e9dure de recherche de pannes qui permet d'\u00e9conomiser de l'argent<\/strong><\/h2>\n<p>Niveau d'eau en premier. Ensuite, tuyauterie et vannes. Puis, tension du g\u00e9n\u00e9rateur par rapport \u00e0 la limite du contr\u00f4leur. Le moteur intervient en dernier, mesur\u00e9 \u00e0 ses bornes.<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"192\"><strong>Sympt\u00f4me<\/strong><\/td>\n<td width=\"192\"><strong>Ce que cela signifie habituellement<\/strong><\/td>\n<td width=\"192\"><strong>Premier contr\u00f4le<\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"192\">Voyage \u00e0 blanc qui se d\u00e9roule dans l'apr\u00e8s-midi<\/td>\n<td width=\"192\">Le niveau de l'eau est descendu en dessous de la pompe.<\/td>\n<td width=\"192\">\u00c9crivez, mesurez, comparez avec le jour de l'installation<\/td>\n<\/tr>\n<tr>\n<td width=\"192\">D\u00e9clenchement par surtension par une matin\u00e9e fra\u00eeche<\/td>\n<td width=\"192\">Les cellules froides poussent la tension de la cha\u00eene au-del\u00e0 de la limite d'entr\u00e9e<\/td>\n<td width=\"192\">Tension en circuit ouvert par rapport \u00e0 la limite \u00e0 la temp\u00e9rature la plus basse du matin<\/td>\n<\/tr>\n<tr>\n<td width=\"192\">D\u00e9clenchement en cas de surcharge lorsque le niveau baisse<\/td>\n<td width=\"192\">Turbine us\u00e9e ou sable dans l'eau<\/td>\n<td width=\"192\">Retirez la pompe et inspectez le bord d'attaque de la turbine.<\/td>\n<\/tr>\n<tr>\n<td width=\"192\">Voyage en haute temp\u00e9rature tous les apr\u00e8s-midi<\/td>\n<td width=\"192\">Contr\u00f4leur install\u00e9 en plein soleil<\/td>\n<td width=\"192\">Toile d'ombrage et d\u00e9gagement de 30 centim\u00e8tres au niveau du dissipateur thermique<\/td>\n<\/tr>\n<tr>\n<td width=\"192\">Mort apr\u00e8s une temp\u00eate<\/td>\n<td width=\"192\">\u00c9clair du c\u00f4t\u00e9 CC<\/td>\n<td width=\"192\">Pr\u00e9sence d'eau dans le bo\u00eetier ou borne br\u00fbl\u00e9e\u00a0; remplacer et ajouter une protection contre les surtensions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>N'ouvrez le contr\u00f4leur qu'ensuite. Dans la plupart des rapports d'intervention, le contr\u00f4leur est le cinqui\u00e8me \u00e9l\u00e9ment suspect\u00e9 et le premier \u00e0 \u00eatre remplac\u00e9.<\/p>\n<p>Notez ce qui a d\u00e9clench\u00e9 l'alerte et \u00e0 quel moment. Trois d\u00e9clenchements \u00e0 11 h du matin indiquent un probl\u00e8me d'eau. Trois \u00e0 14 h, un probl\u00e8me de chaleur.<\/p>\n<p>L'horloge en est la preuve. La plupart des gens ne la regardent jamais.<\/p>\n<h2><strong>En r\u00e9sum\u00e9<\/strong><\/h2>\n<p>La plupart des pannes de pompes sont dues \u00e0 des probl\u00e8mes d'eau, de tuyauterie ou de tension, le tout \u00e9tant masqu\u00e9 par un dispositif de contr\u00f4le.<\/p>\n<p>Zhejiang SOONEST New Energy Co., Ltd. fabrique des pompes et des panneaux pour ces installations. Forte de vingt ans d'exp\u00e9rience dans le photovolta\u00efque, l'entreprise produit sur un site de 4\u00a0000 m\u00b2 \u00e0 Foshan et dispose de plus de 50 brevets de recherche et d\u00e9veloppement. Elle est certifi\u00e9e CE, RoHS, UL, SONCAP et ISO et propose r\u00e9guli\u00e8rement des programmes OEM et ODM aux distributeurs et aux \u00e9quipes EPC.<\/p>\n<p>L'\u00e9quipe technique travaille \u00e0 partir de trois donn\u00e9es\u00a0: l'emplacement du site, la hauteur manom\u00e9trique et le volume quotidien de production \u00e0 d\u00e9placer. Elle v\u00e9rifie la compatibilit\u00e9 du syst\u00e8me avec le contr\u00f4leur avant toute exp\u00e9dition.<\/p>\n<p>La gamme de pompes commence <strong><a href=\"https:\/\/www.soonestpower.com\/fr\/product-category\/applications-domestiques\/pompe-solaire\/\"><u>ici<\/u><\/a><\/strong>Les panneaux sont d\u00e9crits <strong><a href=\"https:\/\/www.soonestpower.com\/fr\/product\/mono-plus-tot-un-350w-450w-550w-575w-585w-panneau-dalimentation-solaire-photovoltaique\/\"><u>ici<\/u><\/a><\/strong>et le stockage <strong><a href=\"https:\/\/www.soonestpower.com\/fr\/product\/serie-aio\/\"><u>ici<\/u><\/a><\/strong>.<\/p>\n<h2><strong>FAQ (questions fr\u00e9quentes)<\/strong><\/h2>\n<h3><strong>Une pompe solaire peut-elle fonctionner sans r\u00e9gulateur ?<\/strong><\/h3>\n<p>Non. Le contr\u00f4leur assure le suivi et la commutation. Il est le seul \u00e9l\u00e9ment entre le g\u00e9n\u00e9rateur photovolta\u00efque et le moteur. Si on le court-circuite, la pompe grille.<\/p>\n<h3><strong>Quelle doit \u00eatre la dur\u00e9e du d\u00e9lai de red\u00e9marrage\u00a0?<\/strong><\/h3>\n<p>R\u00e9glez le d\u00e9lai en fonction du taux de remplissage du forage, ce qui, pour la plupart des puits, correspond \u00e0 plusieurs minutes plut\u00f4t qu'\u00e0 quelques secondes. Des d\u00e9lais trop courts font red\u00e9marrer la pompe dans un puits qui ne s'est pas rempli, et chaque red\u00e9marrage inutile r\u00e9duit la dur\u00e9e de vie du moteur.<\/p>\n<h3><strong>Un parafoudre est-il n\u00e9cessaire\u00a0?<\/strong><\/h3>\n<p>En zone orageuse, oui, et il doit \u00eatre branch\u00e9 c\u00f4t\u00e9 courant continu \u00e0 l'entr\u00e9e du contr\u00f4leur. Il est moins cher que le contr\u00f4leur et bien moins cher qu'une pompe.<\/p>\n<h3><strong>Un contr\u00f4leur plus puissant est-il la solution aux d\u00e9clenchements en cas de surcharge\u00a0?<\/strong><\/h3>\n<p>Rarement. Une surcharge signifie que le moteur est surmen\u00e9, et un contr\u00f4leur plus puissant ne fait que gagner du temps, car la turbine ou le puits finira par c\u00e9der.<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>A controller that trips is usually the messenger, not the culprit. The water level fell. The impeller wore thin. A cold morning pushed string voltage past the input limit. Or the box is bolted up where the afternoon sun beats on it all day. On the distributor&#8217;s side of the counter, the controller gets blamed [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3886,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[57,65],"tags":[],"class_list":["post-3885","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/posts\/3885","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/comments?post=3885"}],"version-history":[{"count":3,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/posts\/3885\/revisions"}],"predecessor-version":[{"id":3892,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/posts\/3885\/revisions\/3892"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/media\/3886"}],"wp:attachment":[{"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/media?parent=3885"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/categories?post=3885"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.soonestpower.com\/fr\/wp-json\/wp\/v2\/tags?post=3885"}],"curies":[{"name":"WP","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}