{"id":3681,"date":"2026-09-28T00:00:49","date_gmt":"2026-09-27T16:00:49","guid":{"rendered":"https:\/\/www.soonestpower.com\/?p=3681"},"modified":"2026-09-28T17:49:52","modified_gmt":"2026-09-28T09:49:52","slug":"how-to-plan-a-100-kw-215-kwh-ci-energy-storage-system-for-african-factories","status":"publish","type":"post","link":"https:\/\/www.soonestpower.com\/pt\/how-to-plan-a-100-kw-215-kwh-ci-energy-storage-system-for-african-factories\/","title":{"rendered":"Como planejar um sistema de armazenamento de energia comercial e industrial de 100 kW e 215 kWh para f\u00e1bricas africanas"},"content":{"rendered":"<p>Um sistema de armazenamento de energia comercial e industrial (C&amp;I) de 100 kW e 215 kWh deve ser planejado com base no perfil de carga medido em f\u00e1brica, no comportamento em caso de falha e nos limites do gerador, e n\u00e3o apenas na pot\u00eancia nominal do painel. O valor de 100 kW refere-se \u00e0 pot\u00eancia m\u00e1xima de carga ou descarga; 215 kWh \u00e9 a energia nominal armazenada. A rela\u00e7\u00e3o entre esses valores sugere aproximadamente 2,15 horas de opera\u00e7\u00e3o em pot\u00eancia m\u00e1xima antes dos limites de reserva e das perdas de convers\u00e3o. Na pr\u00e1tica, o sistema pode ser mais vantajoso quando atenua picos de demanda de curta dura\u00e7\u00e3o, suporta uma barra de carga cr\u00edtica definida e atrasa a partida dos geradores. Defina primeiro a aplica\u00e7\u00e3o pr\u00e1tica e, em seguida, verifique a energia utiliz\u00e1vel, os pain\u00e9is el\u00e9tricos, os controles, as medidas de seguran\u00e7a e os crit\u00e9rios de aceita\u00e7\u00e3o.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3687\" src=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/How-to-Plan-a-100-kW-215-kWh-CI-Energy-Storage-System-for-African-Factories.webp\" alt=\"Como planejar um sistema de armazenamento de energia comercial e industrial de 100 kW e 215 kWh para f\u00e1bricas africanas\" width=\"750\" height=\"422\" srcset=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/How-to-Plan-a-100-kW-215-kWh-CI-Energy-Storage-System-for-African-Factories.webp 750w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/How-to-Plan-a-100-kW-215-kWh-CI-Energy-Storage-System-for-African-Factories-300x169.webp 300w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/How-to-Plan-a-100-kW-215-kWh-CI-Energy-Storage-System-for-African-Factories-18x10.webp 18w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/How-to-Plan-a-100-kW-215-kWh-CI-Energy-Storage-System-for-African-Factories-600x338.webp 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/p>\n<h2><strong><b>Principais conclus\u00f5es<\/b><\/strong><\/h2>\n<ul>\n<li>Utilize os dados do medidor de intervalo e os registros do gerador para definir a fun\u00e7\u00e3o da bateria antes de solicitar um or\u00e7amento.<\/li>\n<li>Dimensionar o pico de corte em kW e a dura\u00e7\u00e3o em kWh; n\u00e3o considere as duas classifica\u00e7\u00f5es como intercambi\u00e1veis.<\/li>\n<li>Separe as cargas essenciais para interrup\u00e7\u00f5es de energia da carga total da f\u00e1brica, para que a bateria n\u00e3o seja consumida por equipamentos n\u00e3o essenciais.<\/li>\n<li>Inclua a sequ\u00eancia de prioridades da rede el\u00e9trica, da bateria, do sistema fotovoltaico e do gerador na especifica\u00e7\u00e3o funcional do EMS.<\/li>\n<li>Avalie o sistema em cen\u00e1rios operacionais reais, e n\u00e3o apenas em um teste de inicializa\u00e7\u00e3o do gabinete.<\/li>\n<\/ul>\n<h2><strong><b>Comece com a carga de f\u00e1brica, n\u00e3o com o gabinete.<\/b><\/strong><\/h2>\n<p>Colete dados representativos da demanda da f\u00e1brica ao longo de v\u00e1rias semanas, utilizando o menor intervalo de medi\u00e7\u00e3o dispon\u00edvel. Inclua registros de produ\u00e7\u00e3o normal, trocas de turno, partidas de compressores, motores de grande porte, sistemas de climatiza\u00e7\u00e3o (HVAC), fins de semana, tarifas de energia, interrup\u00e7\u00f5es no fornecimento de energia e registros de consumo de combust\u00edvel e tempo de funcionamento de geradores.<\/p>\n<p>O corte de pico s\u00f3 funciona quando a bateria consegue reconhecer e suprir a parte da carga que ultrapassa uma meta. Suponha que uma usina atinja 420 kW por 45 minutos e queira manter a demanda da rede pr\u00f3xima a 340 kW. A meta de descarga \u00e9 de 80 kW e a energia do lado CA para esse evento \u00e9 de 60 kWh. A demanda da bateria ser\u00e1 maior ap\u00f3s a aplica\u00e7\u00e3o das perdas do PCS (Sistema de Controle de Pot\u00eancia), consumo auxiliar, reserva de estado de carga, toler\u00e2ncia ao envelhecimento e o limite de energia utiliz\u00e1vel do fornecedor.<\/p>\n<p>Repita o c\u00e1lculo para cada pico recorrente e verifique se os picos coincidem com as interrup\u00e7\u00f5es. Um sistema que lida com um evento de 45 minutos pode n\u00e3o se recuperar antes de um segundo evento no mesmo turno.<\/p>\n<h2><strong><b>Separe kW, kWh e energia utiliz\u00e1vel.<\/b><\/strong><\/h2>\n<p>A pot\u00eancia nominal de 100 kW limita a quantidade de demanda que o PCS pode suprir em um determinado momento. Uma varia\u00e7\u00e3o de carga de 160 kW n\u00e3o pode ser totalmente atendida por um PCS de 100 kW, mesmo que a bateria tenha energia suficiente. A capacidade de armazenamento nominal de 215 kWh descreve a capacidade nominal, mas a energia dispon\u00edvel para a carga depende da faixa de estado de carga permitida, da temperatura, da efici\u00eancia de convers\u00e3o, da pol\u00edtica de degrada\u00e7\u00e3o e de qualquer reserva mantida para backup.<\/p>\n<p>Um licitante pode cotar a energia nominal, outro a energia CC utiliz\u00e1vel e um terceiro a energia CA no ponto de conex\u00e3o. Exija que cada valor identifique seu limite de medi\u00e7\u00e3o e condi\u00e7\u00f5es de opera\u00e7\u00e3o. Consulte o guia Soonest relacionado para obter mais informa\u00e7\u00f5es. <a href=\"https:\/\/www.soonestpower.com\/pt\/100-kw-241-kwh-commercial-ess-cabinet-how-to-check-usable-capacity-before-peak-shaving\/\"><strong><u>Arm\u00e1rio comercial de armazenamento de energia (ESS) de 100 kW \/ 241 kWh<\/u><\/strong><\/a>\u00a0Explica por que os compradores devem verificar a capacidade \u00fatil em vez de presumir que a placa de identifica\u00e7\u00e3o corresponde \u00e0 energia fornecida.<\/p>\n<h2><strong><b>Defina redu\u00e7\u00e3o de pico e backup como trabalhos diferentes.<\/b><\/strong><\/h2>\n<h3><strong><b>Defina um limite de demanda que o servi\u00e7o de emerg\u00eancia m\u00e9dica possa impor.<\/b><\/strong><\/h3>\n<p>Para otimizar o consumo de energia em hor\u00e1rios de pico, o sistema de gerenciamento de energia (EMS) precisa de medi\u00e7\u00f5es de importa\u00e7\u00e3o da rede, um limite de descarga, limites de estado de carga e uma regra de recarga. Uma meta irrealisticamente baixa pode descarregar a bateria prematuramente, enquanto uma meta alta pode resultar em economias n\u00e3o concretizadas.<\/p>\n<p>Identifique se a concession\u00e1ria utiliza uma janela de demanda de 15 minutos, 30 minutos ou outro per\u00edodo. Uma descarga que para muito cedo pode reduzir um pico instant\u00e2neo sem reduzir a demanda faturada.<\/p>\n<h3><strong><b>Construir um barramento de carga cr\u00edtica para interrup\u00e7\u00f5es<\/b><\/strong><\/h3>\n<p>Durante uma interrup\u00e7\u00e3o de energia, forne\u00e7a energia a um painel de carga cr\u00edtica previamente acordado, a menos que toda a planta tenha sido testada dentro dos limites de pot\u00eancia e energia. Os componentes eleg\u00edveis incluem controles, ilumina\u00e7\u00e3o de seguran\u00e7a, equipamentos de produ\u00e7\u00e3o selecionados e cargas de desligamento ordenado. Trate aquecedores, chillers e compressores de grande porte separadamente.<\/p>\n<p>Liste a pot\u00eancia em kW de opera\u00e7\u00e3o, a demanda de partida, o tempo de funcionamento e a sequ\u00eancia de reinicializa\u00e7\u00e3o de cada carga cr\u00edtica. Confirme a curva de sobrecarga do PCS e a coordena\u00e7\u00e3o da prote\u00e7\u00e3o; a partida do motor e a corrente de pico do transformador podem exceder a demanda em regime permanente.<\/p>\n<h2><strong><b>Coordenar a bateria com o gerador a diesel<\/b><\/strong><\/h2>\n<p>O armazenamento em baterias pode reduzir o tempo de funcionamento do gerador, mas uma sequ\u00eancia h\u00edbrida confi\u00e1vel precisa de mais do que uma chave de transfer\u00eancia autom\u00e1tica. Defina quando a bateria forma ou alimenta o barramento da planta, qual estado de carga aciona a partida do gerador, por quanto tempo o gerador deve funcionar antes de aceitar carga e se ele pode carregar a bateria enquanto alimenta a f\u00e1brica.<\/p>\n<p>Uma sequ\u00eancia pr\u00e1tica pode reservar energia para interrup\u00e7\u00f5es curtas e ligar o gerador somente quando a interrup\u00e7\u00e3o persistir ou o estado de carga atingir um n\u00edvel m\u00ednimo. Obtenha os limites m\u00ednimos de carga, aquecimento, resfriamento e pot\u00eancia junto aos fornecedores do gerador e do sistema de controle de pot\u00eancia (PCS). A falta de coordena\u00e7\u00e3o pode causar partidas repetidas, alarmes de pot\u00eancia reversa ou instabilidade de frequ\u00eancia.<\/p>\n<p>Ao analisar o <a href=\"https:\/\/www.soonestpower.com\/pt\/product\/\"><strong><u>Portf\u00f3lio de produtos mais pr\u00f3ximo<\/u><\/strong><\/a>Solicite um diagrama unifilar espec\u00edfico para o projeto e uma descri\u00e7\u00e3o detalhada do sistema de armazenamento de energia (ESS) proposto para uso comercial e industrial. O gabinete mostrado aqui \u00e9 relevante para f\u00e1bricas que precisam de um bloco de pot\u00eancia definido de 100 kW e aproximadamente duas horas de energia nominal, mas a adequa\u00e7\u00e3o final depende da documenta\u00e7\u00e3o de energia utiliz\u00e1vel, das normas de rede, dos equipamentos de manobra, do gerenciamento t\u00e9rmico e do estudo de carga, e n\u00e3o apenas da pot\u00eancia nominal.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3685\" src=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/60kw-112kwh-CI-ESS-Cabinet.webp\" alt=\"Arm\u00e1rio ESS C&amp;I de 60 kW e 112 kWh\" width=\"750\" height=\"422\" srcset=\"https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/60kw-112kwh-CI-ESS-Cabinet.webp 750w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/60kw-112kwh-CI-ESS-Cabinet-300x169.webp 300w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/60kw-112kwh-CI-ESS-Cabinet-18x10.webp 18w, https:\/\/www.soonestpower.com\/wp-content\/uploads\/2026\/09\/60kw-112kwh-CI-ESS-Cabinet-600x338.webp 600w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><\/p>\n<h2><strong><b>Antes de fazer o pedido, descreva o escopo dos servi\u00e7os el\u00e9tricos e de controle.<\/b><\/strong><\/h2>\n<p>Defina o ponto de conex\u00e3o, tens\u00e3o, frequ\u00eancia, aterramento, n\u00edvel de curto-circuito, capacidade do transformador, localiza\u00e7\u00e3o do TC (transformador de corrente), interfaces de prote\u00e7\u00e3o e se o sistema fotovoltaico, a rede el\u00e9trica, o gerador e a bateria compartilham um barramento CA. Atribua responsabilidades por disjuntores, medi\u00e7\u00e3o, cabeamento, comunica\u00e7\u00f5es, obras civis, ventila\u00e7\u00e3o, detec\u00e7\u00e3o de inc\u00eandio e desligamento de emerg\u00eancia.<\/p>\n<p>Solicite uma lista completa de sinais para o BMS, PCS, EMS, medidor de energia, inversor fotovoltaico, controlador de gerador e sistema do local. Informe a resposta em caso de falha de comunica\u00e7\u00e3o. Defina o acesso remoto, as fun\u00e7\u00f5es de usu\u00e1rio, o hist\u00f3rico de alarmes e a exporta\u00e7\u00e3o de dados antes do comissionamento.<\/p>\n<p>O <a href=\"https:\/\/www.soonestpower.com\/pt\/suporte-de-servico\/\"><strong><u>P\u00e1gina de suporte ao cliente mais pr\u00f3xima<\/u><\/strong><\/a>\u00a0Descreve o projeto, a inspe\u00e7\u00e3o, a resolu\u00e7\u00e3o de problemas e o suporte \u00e0 manuten\u00e7\u00e3o. Para um projeto de C&amp;I (Comercial e Industrial), converta esses servi\u00e7os abrangentes em entreg\u00e1veis \u200b\u200bespec\u00edficos: desenhos aprovados, arquivos de configura\u00e7\u00e3o, relat\u00f3rios de teste, treinamento de operadores, lista de pe\u00e7as de reposi\u00e7\u00e3o, m\u00e9todo de suporte remoto e responsabilidades de resposta.<\/p>\n<h2><strong><b>Verifique as condi\u00e7\u00f5es do local e os limites de seguran\u00e7a.<\/b><\/strong><\/h2>\n<p>Confirme a temperatura ambiente, a exposi\u00e7\u00e3o solar, a presen\u00e7a de poeira, a umidade, a drenagem, o n\u00edvel de inunda\u00e7\u00e3o, a corros\u00e3o, a folga de acesso, a rota de i\u00e7amento e o afastamento de \u00e1reas ocupadas ou de alto risco. O fornecedor deve informar os limites ambientais e a redu\u00e7\u00e3o de capacidade.<\/p>\n<p>O plano de combate a inc\u00eandio deve estar em conformidade com as normas locais e o projeto dos equipamentos. Defina os procedimentos de detec\u00e7\u00e3o, roteamento de alarmes, ventila\u00e7\u00e3o, isolamento, resposta a emerg\u00eancias, sinaliza\u00e7\u00e3o e acesso de pessoal treinado. Verifique os requisitos junto \u00e0 autoridade local, seguradora e corpo de bombeiros.<\/p>\n<h2><strong><b>Comiss\u00e3o com cen\u00e1rios operacionais reais<\/b><\/strong><\/h2>\n<p>A aceita\u00e7\u00e3o deve comprovar a polaridade do medidor, carga e descarga, limites do estado de carga, resposta ao corte de pico, perda de rede, solicita\u00e7\u00e3o de partida do gerador, retorno \u00e0 rede, perda de comunica\u00e7\u00e3o, alarmes, parada de emerg\u00eancia e recupera\u00e7\u00e3o de desligamento. Registre pot\u00eancia, energia, estado de carga, tens\u00e3o, frequ\u00eancia e os hor\u00e1rios dos eventos.<\/p>\n<p>Execute pelo menos um teste com cargas representativas de f\u00e1brica. Uma energiza\u00e7\u00e3o sem carga confirma a fia\u00e7\u00e3o, mas n\u00e3o o desempenho do controle. Fa\u00e7a backup das configura\u00e7\u00f5es, verifique a recupera\u00e7\u00e3o do alarme e comprove o isolamento seguro. Use o Soonest's <a href=\"https:\/\/www.soonestpower.com\/pt\/categoria\/solutioncases\/\"><strong><u>biblioteca de solu\u00e7\u00f5es e casos<\/u><\/strong><\/a>\u00a0Como ponto de partida, \u00e9 necess\u00e1rio apresentar evid\u00eancias espec\u00edficas para o local proposto.<\/p>\n<h2><strong><b>Elabore o argumento comercial a partir dos custos evitados mensurados.<\/b><\/strong><\/h2>\n<p>O modelo financeiro deve separar a economia na tarifa de demanda, a mudan\u00e7a de hor\u00e1rio de consumo, a redu\u00e7\u00e3o do consumo de diesel e da manuten\u00e7\u00e3o, a preven\u00e7\u00e3o de interrup\u00e7\u00f5es na produ\u00e7\u00e3o e qualquer valor proveniente do autoconsumo de energia fotovoltaica. Cada benef\u00edcio requer sua pr\u00f3pria premissa operacional, para que dois benef\u00edcios n\u00e3o sejam contabilizados para o mesmo quilowatt-hora armazenado.<\/p>\n<p>Teste picos mais baixos, interrup\u00e7\u00f5es mais frequentes, produ\u00e7\u00e3o sazonal, reserva, degrada\u00e7\u00e3o, consumo auxiliar e varia\u00e7\u00f5es no pre\u00e7o do combust\u00edvel. Uma cota\u00e7\u00e3o robusta relaciona equipamentos, controles, condi\u00e7\u00f5es de garantia e escopo de servi\u00e7o a um perfil de carga que o comprador pode verificar.<\/p>\n<h2><strong><b>Conclus\u00e3o<\/b><\/strong><\/h2>\n<p>Um sistema de armazenamento de energia comercial e industrial de 100 kW \/ 215 kWh pode suportar redu\u00e7\u00e3o de picos de demanda, backup de cargas cr\u00edticas e coordena\u00e7\u00e3o com motores a diesel, mas essas fun\u00e7\u00f5es competem pela mesma pot\u00eancia e energia. Comece com dados de f\u00e1brica medidos, atribua a reserva explicitamente, especifique a sequ\u00eancia de opera\u00e7\u00e3o e teste o sistema final considerando os eventos relevantes no local. <a href=\"https:\/\/www.soonestpower.com\/pt\/\"><strong><u>Mais cedo<\/u><\/strong><\/a><strong><u>\u00a0<\/u><\/strong>Dessa forma, \u00e9 poss\u00edvel analisar o perfil de carga, o diagrama unifilar, a tarifa, o registro de interrup\u00e7\u00f5es e os dados do gerador em rela\u00e7\u00e3o a uma configura\u00e7\u00e3o de sistema adequada, em vez de depender apenas da sele\u00e7\u00e3o com base na placa de identifica\u00e7\u00e3o.<\/p>\n<h2><strong><b>FAQ<\/b><\/strong><\/h2>\n<h3><strong><b>Por quanto tempo uma bateria de 100 kW \/ 215 kWh pode funcionar com pot\u00eancia m\u00e1xima?<\/b><\/strong><\/h3>\n<p>A rela\u00e7\u00e3o nominal simples \u00e9 de 2,15 horas, mas esse n\u00e3o \u00e9 um tempo de funcionamento CA garantido. Limites de estado de carga utiliz\u00e1vel, perdas do PCS, cargas auxiliares, temperatura, pol\u00edtica de envelhecimento e reserva de backup reduzem a energia dispon\u00edvel para a f\u00e1brica. Use a energia CA utiliz\u00e1vel garantida pelo fornecedor para o c\u00e1lculo final do tempo de funcionamento.<\/p>\n<h3><strong><b>Um sistema de armazenamento de energia (ESS) de 100 kW pode substituir um gerador a diesel em uma f\u00e1brica?<\/b><\/strong><\/h3>\n<p>Somente se a carga cr\u00edtica, a demanda inicial, a dura\u00e7\u00e3o da interrup\u00e7\u00e3o e a reserva necess\u00e1ria estiverem dentro dos limites do PCS (Sistema de Controle de Pot\u00eancia) e da energia utiliz\u00e1vel. Muitas f\u00e1bricas obt\u00eam melhores resultados utilizando a bateria para interrup\u00e7\u00f5es curtas e transi\u00e7\u00f5es controladas, enquanto mant\u00eam o gerador para eventos mais longos.<\/p>\n<h3><strong><b>Que dados uma f\u00e1brica deve enviar com um pedido de cota\u00e7\u00e3o de ESS?<\/b><\/strong><\/h3>\n<p>Enviar dados de carga intervalar, tarifas de servi\u00e7os p\u00fablicos, diagramas unifilares, tens\u00e3o e frequ\u00eancia, detalhes de transformadores e geradores, registros de interrup\u00e7\u00f5es, prioridades de carga cr\u00edtica, condi\u00e7\u00f5es do local, espa\u00e7o dispon\u00edvel, informa\u00e7\u00f5es sobre sistemas fotovoltaicos e os cen\u00e1rios necess\u00e1rios para redu\u00e7\u00e3o de pico e backup.<\/p>","protected":false},"excerpt":{"rendered":"<p>A 100 kW 215 kWh C&amp;I energy storage system should be planned from the factory&#8217;s measured load profile, outage behavior, and generator limits, not from the cabinet rating alone. The 100 kW figure is maximum charge or discharge power; 215 kWh is nominal stored energy. Their ratio suggests about 2.15 hours at full power before [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3687,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[57,65],"tags":[],"class_list":["post-3681","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","category-news"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/posts\/3681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/comments?post=3681"}],"version-history":[{"count":3,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/posts\/3681\/revisions"}],"predecessor-version":[{"id":3689,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/posts\/3681\/revisions\/3689"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/media\/3687"}],"wp:attachment":[{"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/media?parent=3681"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/categories?post=3681"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.soonestpower.com\/pt\/wp-json\/wp\/v2\/tags?post=3681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}